Busbar Trunking: Advantages over Cable (1)

When comparing the total estimated cost of the power supply system with cabling and trunking using the same user, the cost of installation and materials system not only exceeds the cost of cabling, but in some cases much lower, and taking the time factor into account, busbars are simply irreplaceable. Below are some of the benefits.

 

Busbars systems have a compact design. Compactness of the arrangement provides reliably isolated and tightly compressed flat conductors inside the enclosure. Bus systems require less space than the cable systems, especially at loads in the hundreds or thousands of amperes

 

Tightly compressed tires, enclosed in metal casing with a well-developed surface, can take a well-produced heat to the walls of the enclosure and from the environment. Cooling is better than cable systems.

 

The modular design of busbar systems is flexible and mobile, allows you to apply it to buildings or structures of any type and configuration, with busbar systems, you can easily modify, add or move to another room, building, and reinstall it without any capital expenditure.

 

Mounting willingness busbar systems is significantly higher than that of cable. This provides a much lower cost of installation and use less time while working on the tire mounting

 

Rigid design elements of the system provides increased resistance to short-circuit compared to cable systems (for example, busbar 3000A: 264 kA and 120 kA peak thermal value of the current short-circuit)

 

The minimum distance between the axes of the conductors reduces the induction of resistance, and the flat, relatively thin tire contributes to the optimal distribution of current density in it (crowding-out effect at high current loads to the surface is peculiar and minimal to cable systems), which lowers resistance. As a result of low levels of resistance and impedance, voltage loss at one and the same length of busbar systems is significantly lower than in cable systems

 

Low resistance values in the busbar system helps to reduce the loss of active energy and limit the growth of reactive power to operate, compared to cable systems

 

Compact design and steel shell provides a significantly lower electromagnetic field around the bus system compared to c cable. Tire system of high load (4000A – 5000A) can be safely installed near the data cables and does not create electromagnetic interference in an information system

 

Typically, a particularly high amperage use multiple cables for connecting one phase, where the cables can vary both in length and at the location and connection. Busbar systems eliminate the difference in length between the conductors that have the exact parameters of the active and inductive reactance, and ensure that the load on each phase is maximum equal. Cable systems cannot be strictly parameterized

 

With busbar power system, it can be easily, efficiently and safely distributed on the line with the junction boxes in places where it is needed. Location data junction boxes can be easily and safely changed if necessary in the future. In addition, there is always the possibility of increasing the number of junction boxes

 

Bus systems consist of fully certified standard cells, where everything is made to eliminate human error. For example, junction boxes and plugs are tested and certified parts of the busbar system and meet all safety requirements. The reliability of the adherence of all junction boxes are standardized and does not depend on the installation. Security Connection cable systems depends on the experience of the installer

 

Busbar systems cannot be damaged by various rodents, which prevents the steel casing, unlike the unprotected cable systems